Heat Transfer

Integrated HTX Refurbishment Solution

Customer: Repsol Sinopec

Location: Onshore North Sea

Integrated HTX Refurbishment Solution
Published in Heat Transfer

Challenge

Glacier Energy was required to carry out a complete overhaul of a 12 x 50ft heat exchanger. 

The biggest challenge was completing the work on each of the exchangers, which were over 50ft x 4ft in size and weighed over 25 tonnes, in a confined working area.

Solutions

  • Refurbishment of 12 x E140 Stabiliser Side Reboiler Heat Exchangers
  • Glacier Energy re-tubed complete units, replacing tubes, baffles, tie rods and spacers and machined all gasket faces
  • Carried out NDT using UT, MOI and IPEK techniques on 100% welds and carried out thickness checks on the shell using a Rovver 225 camera crawler system

Benefits

Due to pull through of in-house services of onsite machining and NDT, Glacier Energy delivered cost efficiencies to customer.

See All Heat Transfer Projects